Pelvis (Female) Protocols

Needs a lot of help

Pelvis (Female): Uterine/Vaginal abnormality

Preparation:

  • Fast at least 4 hours prior to exam
  • Empty the bladder before scan
  • Coverage – from iliac crest to pubic symphysis
  • Adjust slice thickness (3-­‐5mm typically) and matrix to pt size and scan time requirements

Sequences:

Sequence Name

Vendor Specific name

Plane

Fat supp ressi

on

Motion compensation

Other relevant paramet

ers

Additional info

T2 radial

BLADE/P ROPELLE

R/MultiV ane

Coronal oblique/ parallel to long axis of uterine

corpus

No

Radial acq

Add forced recovery pulse to dec scan

time

Consider isotopic variant (SPACE/CUB

E/VISTA if pt

cooperative)

T2 radial

BLADE/P ROPELLE

R/MultiV ane

Axial Sagittal

No

Radial acq

Add forced recovery pulse to

dec scan time

Consider isotopic variant (SPACE/CUB

E/VISTA if pt cooperative)

T2 radial

BLADE/P ROPELLE

R/MultiV ane

Axial Sagittal

No

Radial acq

Add forced recovery pulse to

dec scan time

Consider isotopic variant (SPACE/CUB

E/VISTA if pt cooperative)

T1

T1

Axial

No

 

 

 

T1 3D GRE

VIBE/LA

VA/THRI

VE

Axial

Coronal

Sagittal

Yes

BH

Pre and

post

contrast

Consider

multiphase

dynamic

imaging in

Sag plane

followed by delays in Ax and Cor


 

  • Optional sequences: 1) Isotopic T2 (SPACE/CUBE/VISTA) can be acquired once and reconstructed in all 3 planes; 2) Sag bSSFP (TrueFISP/FIESTA/balanced FFE) instead of sag T2.

 

 Pelvis (Female): Ovarian mass 

Preparation:

  • Fast at least 4 hours prior to exam
  • Empty the bladder before scan
  • Coverage – from iliac crest to pubic symphysis
  • Adjust slice thickness (3-­‐5mm typically) and matrix to pt size and scan time requirements

 

 

Sequences:

 

Sequence Name

Vendor Specific name

Plane

Fat supp ressi on

Motion compensatio n

Other relevan t parame

ters

Additional info

T2 radial

BLADE/P

ROPELLE

R/MultiV

ane

Axial

No

Radial acq

Add

forced

recover

y pulse

to dec

scan

time

Consider

isotopic

variant

(SPACE/CUBE/

VISTA if pt

cooperative)


T2 radial

BLADE/P ROPELLE

R/MultiV ane

Coronal

No

Radial acq

Add forced recover y pulse to dec scan

time

Consider isotopic variant (SPACE/CUBE/

VISTA if pt cooperative)

T2 radial

BLADE/P ROPELLE

R/MultiV ane

Coronal

No

Radial acq

Add forced recover y pulse to dec

scan time

Consider isotopic variant (SPACE/CUBE/

VISTA if pt cooperative)

T1 Dixon

T1 in-­‐

opp phase

Axial

No

None

 

 

T1 FS

FSE

Axial

Yes

None

 

Good for detecting endometrioma

s

DWI

 

Axial

No

None

 

Us 3 B-­‐values

up to 800

T1 FS 3D GRE

VIBE/TH RIVE/LA VA

Axial Coronal Sagittal

Yes

BH

Pre-­‐ post contrast

Us obtain multiphase Axial acq followed by sag/cor delays

 

  

  • Optional sequences: 1) Isotopic T2 (SPACE/CUBE/VISTA) can be acquired once and reconstructed in all 3 planes; 2) Sag bSSFP (TrueFISP/FIESTA/balanced FFE) instead of sag T2.